登录

  • 登录
  • 忘记密码?点击找回

注册

  • 获取手机验证码 60
  • 注册

找回密码

  • 获取手机验证码60
  • 找回
毕业论文网 > 毕业论文 > 土木建筑类 > 给排水科学与工程 > 正文

南京某医院给水排水工程设计毕业论文

 2022-06-04 10:06  

论文总字数:29762字

摘 要

给水系统分区供水,从市政管网上接一根DN100的引入管,负一层至地上四层为市政管网直供,五至九层采用无负压变频供水设备加压供水,并预留DN65给水管供空调机房用水。消防水池采用钢筋混凝土结构,置于地下室泵房外侧,有效容积432立方。建筑室内排水采用污、雨水分流制,室外排水采用污废合流制,排入检查井后,经化粪池处理再排入市政污水管。卫生间采用多设立管形式,采用专用通气立管,部分增设环形通气管。地下室排水经排水沟汇集排至集水坑,经潜污泵提升排至检查井。建筑立面为全玻幕墙,采用内排水,选择重力半有压流系统,雨水经屋面雨水斗收集后由雨水管排至检查井。

根据规范,该建筑为一类高层建筑,室外消火栓用水量20L/s,室内消火栓用水量30L/s,火灾延续时间2h。消火栓充实水柱高度12m,水龙带长度25m,水枪喷嘴流量5.16L/s,消防立管管径为DN100。在屋顶层设试验消火栓一个,每个室内消火栓箱内均设有远距离启动消防泵的按钮。

该建筑采用湿式自动喷水灭火系统,喷淋系统设计流量40L/s。报警阀设于地下室泵房内,各层均设水流指示器、末端试水装置和信号阀,其信号均送入消防控制中心进行处理。本工程的自动喷水灭火系统分2个区。选用箱泵一体化消防增压稳压设备(包含18立方米消防水箱)贮存火灾初期10min自动喷水灭火系统、室内消火栓系统用水量,初期灭火由水箱供水,后期灭火由地下室的消防水泵和喷淋泵供水。

关键词:给水系统、排水系统、消火栓系统、自动喷水灭火系统、雨水系统

Abstract

Water supply system water, from municipal pipe network pick a service pipe DN100, minus one to five floors for the direct supply of municipal pipe network, six to ten layers with no negative-pressure variable-frequency water supply equipment pressurized water DN65 pipe for air conditioner for computer room and reserved water. Fire pool used for reinforced concrete structures placed in basement pumping station outside the effective volume 432 cubic. Construction indoor drainage-diversion of sewage, waste water, an outdoor drainage sewage waste combined, after discharged into the manhole, septic tank treatment and then discharged into municipal sewers. Toilet multi-established forms, special ventilation risers, some additional loop vent. Basement drainage flow sewer collection to sump, submersible sewage pump lifting flows into the inspection Chamber. For the whole glass curtain wall building facades, internal drainage, select half-pressure of gravity flow systems, rainwater flow roof rainwater collected by the rain water pipe to manhole.
According to the specifications, the building two high-rise construction, outdoor fire hydrant water 20L/s, 30L/s fire hydrant water consumption, fire life 2h. 12m fire hydrant full water column height, hose length 25m, 5.16L/s water gun nozzle flow, fire the riser tube diameter DN100. Set up a test fire hydrants in roofing, each fire hydrant boxes are equipped with remote start button for fire pump.
Wet automatic fire sprinkler system in the building, spraying system design flow 40L/s. The alarm valve located on the pump room in the basement, the floors are located water flow indicator, test water device and signal the valve at the end, its signal is fed into the fire control centre for processing. Sprinkler system the project divided into 3 zones. Selection box-pump fire booster regulator device integration (including 18 cubic metres of fire water tank) storage initial 10min sprinkler system for fire water, indoor fire hydrant system, initial fire-fighting water tank water supply, late extinguishing the fire pump and sprinkler pumps water from the basement

Keyword: water-supply system、drainage system、hydrant system、automatic sprinkler system、rainwater system

目 录

第一章 设计说明书

摘 要 I

Abstract II

一、给水系统 1

1.1给水方式选择 1

1.2给水系统分区 1

1.3管材 1

1.4给水系统组成 1

1.5给水管道布置与安装 2

二、消防系统 2

2.1室内消火栓系统 2

2.1.1室内消火栓系统的选择 2

2.1.2系统组成 3

2.1.3设备及构筑物 3

2.1.4消火栓的安装 3

2.2自动喷淋系统 4

2.2.1室内自动喷水灭火系统的选择 4

2.2.2系统组成 4

2.2.3喷头的选择与布置 4

2.2.4设备及构筑物 5

2.2.5喷淋系统的安装 5

三、室内排水系统 6

3.1系统选择 6

3.2系统组成 6

3.3排水管道安装要求 6

四、雨水系统 7

4.1雨水排水系统的选择 7

4.2雨水排水系统的组成 7

4.3雨水管道的敷设与布置 7

第二章 设计说明书

一、给水系统计算 8

1.1 生活给水系统所需水量 8

1.2 室内给水系统计算 8

二、室内消火栓给水系统的计算 13

2.1消防水池 13

2.1.1消防水池的设置 13

2.1.2体积计算 14

2.2屋顶消防水箱 15

2.3消火栓保护半径 15

2.4消火栓布置间距 16

2.5消火栓的确定 16

2.6消火栓的水力计算 16

2.7水泵接合器选定 18

2.8消火栓减压计算 19

2.9室外消火栓的设置 19

三、自动喷水灭火系统 20

3.1计算说明 20

3.2喷头的出流量 20

3.3系统的设计流量 21

3.4理论流量 21

3.5作用面积内的计算平均喷水强度为 21

3.6喷头的保护半径 22

3.7作用面积内最不利点处4个喷头所组成的保护面积 22

3.8管段的总损失 22

3.9喷淋泵的选择 24

四、室内排水系统的设计与计算 25

4.1 各横支管的设计计算 25

4.2 立管的水力计算 32

4.3立管底部和排出管计算 34

4.4 通气管的计算 34

4.5集水坑及提升泵计算选型 34

4.6 化粪池计算 35

五、建筑雨水排水系统的设计与计算 35

设计参数选取 35

5.1 各汇水面积F的划分 36

5.2 设计计算 36

5.2.1顶层屋面雨水排放 36

5.2.2 三层屋面雨水排放 38

参考文献 39

请支付后下载全文,论文总字数:29762字

您需要先支付 80元 才能查看全部内容!立即支付

企业微信

Copyright © 2010-2022 毕业论文网 站点地图