万都科技楼给水排水工程设计毕业论文

 2020-05-23 04:05  

摘 要

该建筑为科技楼,在中国南方,建筑高度为58.60米,总建筑面积约1.8万平方米。本建筑物所有给水排水均按高层建筑给排水要求进行设计。结合实际情况,根据建筑物的性质,用途,和室内设有完善的给水排水卫生设备,具体的给排水系统设计如下:

给水系统:

本建筑地下一层至地上四层由室外市政管网直接供水,六至十七层设有变频调速系统的给水方式;由于消火栓超过十个,需设两条引入管。从不同的方向引入。既保障了供水安全,又节约了能耗。

排水系统:

本设计采用污废水合流排放体制。管材采用了UPVC排水管,采用升顶通气和使用通气立管方式,为此可进一步提高环境质量。地下室内消防电梯井旁、泵房地面均设有集水坑和废水提升装置。

消防系统:

该建筑防火等级属于中危险级Ⅱ级,设计内容包括消火栓系统,自动喷淋。在屋顶水箱间内设实验用消火栓装置,消火栓给水管网呈环状布置,各消火栓箱内设消防水泵启动电钮,能直接启动消防泵;室外设地下式水泵结合器,保证消防安全可靠。地下室,走廊,办公间,电梯前室设闭式自动喷淋系统,

雨水系统:

该建筑为办公楼,屋面较宽,并包括了裙楼。故主要采用雨水内排水方式。

各系统中的立管设在管井内或沿墙敷设,水平管根据各系统的特点明敷或暗敷。

本设计以经济、环保、节能为原则,通过借鉴以前的设计方法和经验,采用了合理的技术措施,使设计的各个系统达到了很好的使用效果。

 

关键词:给水 排水 消火栓 自动喷淋

Abstract

The design of water supply and drainage system

in Wandu science and technology building

This building is a science and technology building, is located southern side the China, the construction is highly 58.60 meters, total floor space approximately 17,000 square meters. This building possesses for water draining water presses the high-rise construction to request for draining water to carry on the design. Unifies the actual situation, according to the building nature, the use, is equipped with the consummation with the room in for the water draining water sanitary equipment, concrete gives the drainage system design to be as follows:

For aqueous system:

This construction underground to ground four by outdoor municipal administration pipe network direct water supply, six to seventeen gives the square water pitcher type which is equipped with the water pump. Because the fire hydrant surpasses ten, must suppose two lead-in tubes. From different direction introduction. Both has safeguarded the water supply security, and saved the energy consumption.

Drainage system:

This design uses the dirt waste water confluence emissions system. The tubing used had the UPVC discharge pipe, rose to go against the ventilation way.Vent stack is used in this system,which might further improve the environment quality for this. In the basement nearby the fire electricity stairwell, the pump house ground are equipped with the sump and the waste water lifting gear.

Fire prevention system:

This building fire protection rank belongs to the dangerous levelⅡThe level, the design content including the fire hydrant system and sprays automatically system. In supposes the experimental fire hydrant installment in the roof water tank between, the fire hydrant service pipe net assumes the ring-like arrangement, in various fire hydrants box supposes the fire pump to start the push-button, can the line start fire extinguishing pump; Room peripheral equation below water pump coupler, guarantee fire prevention safe reliable. The basement, the corridor, the work, in front of the elevator the room supposes the closed type to spray the system automatically.

Rain water system:

This building is an office building, of which the roof is quite wide.This building is also includes a skirt buliding.The construction roofing height dropping variance requires the building mainly to use outside drains water system.

In various systems pipe riser is located in the tube well or along the wall placing, the horizontal tube acts according to various systems to point out especially spreads or spreads darkly.

This design take the economy, the environmental protection, the energy conservation as a principle, through profits from beforehand design method and the experience, has used the reasonable technical measure, enabled the design each system to achieve the very good use effect.

 

Key Words: for water ;Draining off water ;The fire hydrant ;Spurting voluntarily pours .

目 录

摘 要 I

Abstract II

第一章 引 言 1

第二章 工程概况 2

2.1建筑概况 2

2.1.1工程概述 2

2.1.2建筑各层面积以及高度 2

2.2建筑概况 2

2.2.1设计要求 2

2.2.2设计内容 3

2.3设计依据及原始资料 3

2.3.1依据设计 3

2.3.2 原始资料 3

第三章 给水系统的设计与计算 4

3.1 设计说明 4

3.1.1给水方式的选择与优缺点 4

3.1.2给水系统的组成 4

3.1.3给水管道布置与安装 4

3.2设计计算 5

3.2.1生活给水设计标准与参数的确定 5

3.2.2设计流量计算 5

3.2.3低位贮水池设计 6

3.2.4低区管网水力计算 7

3.2.5高区管网水力计算 10

3.2.6引入管选择 18

3.2.7水表选择 18

3.2.8低区给水管JL1水压校核 20

3.2.9高区供水设备选型 20

第四章 建筑排水系统设计与计算 23

4.1设计说明 23

4.1.1确定系统排水体制 23

4.1.2系统组成及管材选用 23

4.1.3存水弯、地漏、清扫口的设置 23

4.1.4防火套管的布置与敷设 23

4.2设计计算 24

4.2.1设计秒流量 24

4.2.2管道布置和敷设: 24

4.2.3各排水立管横支管水力计算 25

4.2.4排水立管的设计与计算 30

4.3排出管 31

4.4集水坑及提升泵计算选型 31

4.4.1汽车坡道集水坑计算 31

4.4.2消防电梯集水坑及提升泵计算选型 31

4.4.3水泵房集水坑及提升泵计算选型 32

4.4.4汽车库集水坑及提升泵计算选型 32

4.5化粪池计算 32

4.5.1污水部分容积 32

4.5.2浓缩污泥部分的容积 33

4.5.3化粪池有效容积 33

4.5.4化粪池选型 33

第五章 建筑雨水排水系统设计与计算 34

5.1设计说明 34

5.1.1确定屋面雨水排出方式 34

5.1.2管材选用 34

5.1.3雨水斗及管道的布置原则与方法: 34

5.1.4降雨强度确定 34

5.2设计计算 34

5.2.1内排水系统计算 34

第六章 建筑消防系统的设计与计算 40

6.1设计说明 40

6.1.1设计参数 40

6.1.2消防系统设计 40

6.2消火栓给水系统 41

6.2.1消火栓给水系统的设计 41

6.2.2消火栓系统的设计 41

6.3 自动喷水系统的设计与计算 46

6.3.1喷头选型 46

6.3.2自动喷水灭火系统组成 46

6.3.3水力计算 46

6.3.4加压设备的选择 49

6.3.5水泵接合器的选择 49

6.3.6喷淋减压计算 49

6.4消防水池、消防水箱及稳压设备 50

6.4.1消防水池的设计 50

6.4.2消防水箱及稳压设备 50

结语 51

参考文献 52

谢 辞 53

第一章 引 言

近年来,随着我国经济实力的增强,生活水平的提高,人们对生活质量,特别是生活空间居住环境的要求也在日益提高。节水节能已经提上日程。这就要求我们建筑给水排水专业人员更加努力。在做好合理设计的同时,更应开放思维,提高节水节能意识,为创和谐社会贡献一份力量。本次毕业设计为高层办公楼的给水,排水,雨水,消防系统的设计与计算。

在给水设计中,结合相关的设计资料提供的数据,本着以经济合理为原则,精确选择供水方案。在给水方面采用多项给水系统和超强节能的变频调速系统,大大增强了给水保障力度,提高了安全系数。排水方面能结合该建筑的特点、市政条件以及周围建筑环境的特点,在设计中力求保证排水畅通,卫生条件较好。在消防方面主要考虑该建筑的防火等级,涉及方面有消火栓系统和自动喷淋系统。在设计中通过各种方式搜集和整理经验数据以及各种资料,力求使设计更加合理,保证各个系统的正常工作。本次设计的主要目的:

掌握并能熟练运用计算机绘制给排水施工图。

相关图片展示: